PRCXI
UltraMicro 8000
High-throughput Workstation

This sample spotting plate can be used for small molecule drugs, nucleic acids, proteins & micro-organisms, before mass  spectrometry analysis. It has a wide range of application in many fields, e.g. high-throughput drug screening, genomics,  proteomics, disease screening, drug sensitivity analysis, pathogenic microbial typing, etc.

It solves the problems of slow manual spotting, unstable spotting volume and inaccurate spotting position, and  utilizes PRCXI's self-developed siphon steel needle module, sterilizing module, cleaning module and drying module  together with high-precision, high-speed and high-stability linear module to achieve fast, micro-volume, accurate  and reliable dispense performance.

Hardware
  • Sterilization module
    Using sodium hypochlorite's ability to interrupt nucleic acid fragments by sterilization, steel needles were immersed in sodium hypochlorite solution for sterilization to prevent stringing of samples.
  • Cleaning module
    Pure water is continuously flushed through the peristaltic pump at the bottom of the steel needle dipping position to ensure that the residual liquid on the steel needle can be flushed clean.
  • Dry module
    Provide high heat and high air velocity air environment, so that the hot air flow through the steel needle at high speed, quickly evaporate the water on the steel needle.
  • 6/24 steel needle module
    Steel needle point sampling is performed by immersing a siphon steel needle into the liquid of the sample plate after the needle has moved to the surface of the mass spectrometry target plate.
Work Process


Product Parameters
Instrument UltraMicro8000 High-Throughput Workstation
Pipetting range 30 - 50 nL
Channels 6/24 Channel Steel Needle Pipetting Module
Disinfection module With sodium hypochlorite's ability to interrupt nucleic acid fragments for sterilization, steel needles are immersed in a sodium hypochlorite solution for sterilization.
Cleaning module Through the pumping action of the peristaltic pump, you can ensure that there is a continuous clean pure water rinse the bottom of the needle dip position to ensure that liquid left on the needle are completely rinsed away.
Drying module In the high-heat and high-velocity air environment, the hot air flows through the needle at high speed, which can quickly evaporate the water left on the needle.
Safety UV sterilizing function, system abnormality alarm function
Interface 1 USB,1 Ethernet ports
Size 760 x 590 x 630mm